Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.110
Filtrar
1.
Trends Hear ; 28: 23312165241246616, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656770

RESUMEN

Negativity bias is a cognitive bias that results in negative events being perceptually more salient than positive ones. For hearing care, this means that hearing aid benefits can potentially be overshadowed by adverse experiences. Research has shown that sustaining focus on positive experiences has the potential to mitigate negativity bias. The purpose of the current study was to investigate whether a positive focus (PF) intervention can improve speech-in-noise abilities for experienced hearing aid users. Thirty participants were randomly allocated to a control or PF group (N = 2 × 15). Prior to hearing aid fitting, all participants filled out the short form of the Speech, Spatial and Qualities of Hearing scale (SSQ12) based on their own hearing aids. At the first visit, they were fitted with study hearing aids, and speech-in-noise testing was performed. Both groups then wore the study hearing aids for two weeks and sent daily text messages reporting hours of hearing aid use to an experimenter. In addition, the PF group was instructed to focus on positive listening experiences and to also report them in the daily text messages. After the 2-week trial, all participants filled out the SSQ12 questionnaire based on the study hearing aids and completed the speech-in-noise testing again. Speech-in-noise performance and SSQ12 Qualities score were improved for the PF group but not for the control group. This finding indicates that the PF intervention can improve subjective and objective hearing aid benefits.


Asunto(s)
Corrección de Deficiencia Auditiva , Audífonos , Ruido , Personas con Deficiencia Auditiva , Inteligibilidad del Habla , Percepción del Habla , Humanos , Masculino , Femenino , Anciano , Ruido/efectos adversos , Persona de Mediana Edad , Corrección de Deficiencia Auditiva/instrumentación , Personas con Deficiencia Auditiva/rehabilitación , Personas con Deficiencia Auditiva/psicología , Enmascaramiento Perceptual , Pérdida Auditiva/rehabilitación , Pérdida Auditiva/psicología , Pérdida Auditiva/diagnóstico , Audiometría del Habla , Encuestas y Cuestionarios , Anciano de 80 o más Años , Factores de Tiempo , Estimulación Acústica , Audición , Resultado del Tratamiento
2.
Acta Otorhinolaryngol Ital ; 44(2): 113-119, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38651553

RESUMEN

Objective: To determine the benefits of binaural hearing rehabilitation in patients with monaural conductive or mixed hearing loss treated with a unilateral bone conduction implant (BCI). Methods: This monocentric study includes 7 patients with monaural conductive or mixed hearing loss who underwent surgical implantation of a unilateral BCI (Bonebridge, Med-El). An ITA Matrix test was performed by each patient included in the study - without and with the BCI and in three different settings - to determine the summation effect, squelch effect and head shadow effect. Subjective hearing benefits were assessed using the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire. Results: The difference in signal to noise ratio of patients without and with BCI was 0.79 dB in the summation setting (p < 0.05), 4.62 dB in the head shadow setting (p < 0.05) and 1.53 dB (p = 0.063) in the squelch setting. The APHAB questionnaire revealed a subjective discomfort in the presence of unexpected sounds in patients using a unilateral BCI (aversiveness score) compared to the same environmental situations without BCI, with a mean discomfort score of 69.00% (SD ± 21.24%) with monaural BCI versus 25.67% (SD ± 16.70%) without BCI (difference: -43.33%, p < 0.05). In terms of global score, patients wearing a unilateral Bonebridge implant did not show any significant differences compared to those without hearing aid (difference: -4.00%, p = 0.310). Conclusions: Our study shows that the use of a unilateral BCI in patients affected by monaural conductive or mixed hearing loss can improve speech perception under noise conditions due to the summation effect and to the decrease of the head shadow effect. However, since monaural BCIs might lead to discomfort under noise conditions in some subjects, a pre-operative assessment of the possible individual benefit of a monaural BCI should be carried out in patients affected by unilateral conductive or mixed hearing loss in order to investigate the possible additional effect of the fitting of hearing aids.


Asunto(s)
Conducción Ósea , Pérdida Auditiva Conductiva , Perdida Auditiva Conductiva-Sensorineural Mixta , Humanos , Femenino , Masculino , Persona de Mediana Edad , Perdida Auditiva Conductiva-Sensorineural Mixta/rehabilitación , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Adulto , Pérdida Auditiva Conductiva/rehabilitación , Pérdida Auditiva Conductiva/cirugía , Pérdida Auditiva Conductiva/fisiopatología , Audífonos , Anciano
4.
Trials ; 25(1): 256, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38610038

RESUMEN

BACKGROUND: Teleaudiology can potentially improve access to hearing healthcare services. Remote hearing aid fittings offer a new mode of service delivery that removes barriers of geography and access to an audiologist. Real-ear measurements (REMs) are the gold standard for hearing aid output verification but require in-clinic appointments. This study will investigate whether remote hearing aid fittings can provide clinically equivalent outcomes when compared to current, in-clinic, best practice guidelines. RESEARCH DESIGN: A repeated measure, double-blinded crossover design will be used. Participants will be randomly allocated to one of two groups to determine order of intervention, balanced for degree of hearing loss. STUDY SAMPLE: Sixty adults with mild to moderate hearing loss and at least 1 year of experience with hearing aids will be recruited. DATA COLLECTION AND ANALYSIS: Participants will complete two hearing aid fitting protocols, one using an in-clinic fitting process and the other using a remote (at-home) fitting process. In-clinic fittings will include REMs with adjustments to standard (NAL-NL2) prescription targets. The two fitting protocols will then be randomly assigned to participants in a crossover design, so participants and researchers will be blinded to the order of the two fitting protocols. Participants will then have a 4-week period with follow-up appointments for participant-directed gain adjustment. For each fitting protocol, participants will complete objective measurements of final hearing aid output with REMs, speech-in-noise testing, subjective measurements of hearing aid performance, and quality of life measurements. They will then begin an identical period of living with, adjusting, and objective assessment with the other fitting protocol. Data will be analysed as repeated measures with statistical control for potential confounding variables. RESULTS: Data will compare the four-frequency average real-ear aided response (4FREAR) for hearing aids programmed in-clinic and hearing aids programmed remotely, after participant-directed gain adjustments. Secondary measures will assess clinically significant differences in estimated speech intelligibility, hearing-related quality of life, hearing aid benefit, sound quality and preference, and speech-in-noise ability. CONCLUSIONS: This study will inform the development of best practice guidelines for remote hearing aid fittings. If no clinically significant differences are found between in-clinic and remote fit hearing aids, it has the potential to expand teleaudiology initiatives. TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry, ACTRN12623000028606p . Date of registration: 12 January 2023.


Asunto(s)
Audífonos , Pérdida Auditiva Sensorineural , Pérdida Auditiva , Adulto , Humanos , Calidad de Vida , Australia , Instituciones de Atención Ambulatoria , Pérdida Auditiva Sensorineural/diagnóstico , Pérdida Auditiva Sensorineural/terapia , Ensayos Clínicos Controlados Aleatorios como Asunto
5.
Cereb Cortex ; 34(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38610087

RESUMEN

Hearing is critical to spoken language, cognitive, and social development. Little is known about how early auditory experiences impact the brain structure of children with bilateral sensorineural hearing loss. This study examined the influence of hearing aid use and residual hearing on the auditory cortex of children with severe to profound congenital sensorineural hearing loss. We evaluated cortical preservation in 103 young pediatric cochlear implant candidates (55 females and 48 males) by comparing their multivoxel pattern similarity of auditory cortical structure with that of 78 age-matched children with typical hearing. The results demonstrated that early-stage hearing aid use preserved the auditory cortex of children with bilateral congenital sensorineural hearing loss. Children with less residual hearing experienced a more pronounced advantage from hearing aid use. However, this beneficial effect gradually diminished after 17 months of hearing aid use. These findings support timely fitting of hearing aids in conjunction with early implantation to take advantage of neural preservation to maximize auditory and spoken language development.


Asunto(s)
Corteza Auditiva , Audífonos , Pérdida Auditiva Sensorineural , Femenino , Masculino , Humanos , Niño , Pérdida Auditiva Sensorineural/terapia , Audición , Encéfalo
6.
Trends Hear ; 28: 23312165241246597, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38629486

RESUMEN

Hearing aids and other hearing devices should provide the user with a benefit, for example, compensate for effects of a hearing loss or cancel undesired sounds. However, wearing hearing devices can also have negative effects on perception, previously demonstrated mostly for spatial hearing, sound quality and the perception of the own voice. When hearing devices are set to transparency, that is, provide no gain and resemble open-ear listening as well as possible, these side effects can be studied in isolation. In the present work, we conducted a series of experiments that are concerned with the effect of transparent hearing devices on speech perception in a collocated speech-in-noise task. In such a situation, listening through a hearing device is not expected to have any negative effect, since both speech and noise undergo identical processing, such that the signal-to-noise ratio at ear is not altered and spatial effects are irrelevant. However, we found a consistent hearing device disadvantage for speech intelligibility and similar trends for rated listening effort. Several hypotheses for the possible origin for this disadvantage were tested by including several different devices, gain settings and stimulus levels. While effects of self-noise and nonlinear distortions were ruled out, the exact reason for a hearing device disadvantage on speech perception is still unclear. However, a significant relation to auditory model predictions demonstrate that the speech intelligibility disadvantage is related to sound quality, and is most probably caused by insufficient equalization, artifacts of frequency-dependent signal processing and processing delays.


Asunto(s)
Audífonos , Pérdida Auditiva , Percepción del Habla , Humanos , Audición , Ruido/efectos adversos
7.
Int J Pediatr Otorhinolaryngol ; 179: 111930, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38579404

RESUMEN

BACKGROUND: Deaf and hard of hearing (DHH) children may experience communication delays, irrespective of early intervention and technology. Australian Sign Language (Auslan) is one approach in early intervention to address language delays. Current prevalence of Auslan use among Australian families with DHH children is unknown. AIMS: The first aim was to determine the proportion of families enrolled in an Australian statewide hearing loss databank who use Auslan with their DHH child. The second aim was to explore the relationships between indicators of child hearing loss (bilateral or unilateral hearing loss, degree of hearing loss, and device use: hearing aids and cochlear implants), family factors (maternal education, attendance at early intervention, family history of deafness, and socio-economic disadvantage) and the family's reported use of Auslan. METHODS: We analysed the enrolment data from 997 families who participated in an Australian statewide hearing loss databank between 2012 and 2021. We described the proportion of families who used Auslan with their DHH child at home. The association between indicators of child hearing loss and family factors, and the parental reports of communication approach were examined using correlation analyses. RESULTS: Eighty-seven of 997 parents (8.7%) reported using Auslan with their DHH child. Of these, 26 (2.6%) used Auslan as their primary language. The use of Auslan at home was associated with the following indicators of child hearing loss: bilateral hearing loss, profound compared to mild hearing loss, and cochlear implant and hearing aid use compared to no device use. The family factors associated with the use of Auslan were: referral or attendance at early intervention compared to those who did not attend, and a family history of deafness compared to those with none. No association was found between maternal education and socio-economic disadvantage and the use of Auslan. CONCLUSION: This Australian study found a low proportion (8.7%) of families with a DHH child who reported using Auslan. Seven child hearing loss and family factors were considered, and five were significantly associated with using Auslan at home. Children with a greater degree of hearing loss, attendance at early intervention and family history of deafness tended to use Auslan.


Asunto(s)
Sordera , Audífonos , Pérdida Auditiva , Personas con Deficiencia Auditiva , Niño , Humanos , Sordera/epidemiología , Sordera/cirugía , Sordera/rehabilitación , Australia/epidemiología , Pérdida Auditiva/epidemiología
9.
J Acoust Soc Am ; 155(4): 2460-2469, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38578178

RESUMEN

Head-worn devices (HWDs) interfere with the natural transmission of sound from the source to the ears of the listener, worsening their localization abilities. The localization errors introduced by HWDs have been mostly studied in static scenarios, but these errors are reduced if head movements are allowed. We studied the effect of 12 HWDs on an auditory-cued visual search task, where head movements were not restricted. In this task, a visual target had to be identified in a three-dimensional space with the help of an acoustic stimulus emitted from the same location as the visual target. The results showed an increase in the search time caused by the HWDs. Acoustic measurements of a dummy head wearing the studied HWDs showed evidence of impaired localization cues, which were used to estimate the perceived localization errors using computational auditory models of static localization. These models were able to explain the search-time differences in the perceptual task, showing the influence of quadrant errors in the auditory-aided visual search task. These results indicate that HWDs have an impact on sound-source localization even when head movements are possible, which may compromise the safety and the quality of experience of the wearer.


Asunto(s)
Audífonos , Localización de Sonidos , Estimulación Acústica , Movimientos de la Cabeza
10.
S Afr J Commun Disord ; 71(1): e1-e8, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38426736

RESUMEN

BACKGROUND:  Bone-conduction hearing devices (BCHD) can provide hearing solutions in settings where middle ear pathology is rife. OBJECTIVES:  Describe functional hearing outcomes and device use of children fitted with BCHD. METHOD:  Retrospective review of 79 children fitted with BCHD between January 2017 and May 2022. Outcomes included device use and subjective reports measured with the Parents' Evaluation of Aural/Oral Performance of Children (PEACH) and the Teachers' Evaluation of Aural/Oral Performance of Children (TEACH). Analysis of variance established association between mean data logging and type and degree of hearing loss. Thematic analyses were done for qualitative outcomes. RESULTS:  Average usage was 7.0 h/day (5.4 SD; range 0.1-24). PEACH ratings indicated 93.3% of children wore their BCHD 'always' or 'often', with 80% displaying Typical auditory performance at 1-month follow-up. TEACH ratings indicated 84.2% of children wore their BCHD 'always' or 'often', with 78.9% showing typical auditory behaviour. Increased usage was noted for conductive, mixed, moderate and severe hearing losses. There was a mean delay of 17.2 months (23.4 SD; range 0-90) between age of diagnosis and fitting. Thematic analyses identified two main themes: advantages and barriers to BCDH use. CONCLUSION:  Average device use fell short of the internationally recommended 10 h/day. Higher BCHD use was associated with higher functional listening performance scores. Long waiting times for medical or surgical intervention for conductive hearing losses can delay BCHD fitting.Contribution: Limited information is available to examine outcomes in children fitted with BCHD.


Asunto(s)
Audífonos , Pérdida Auditiva , Niño , Humanos , Sudáfrica , Conducción Ósea , Oído , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/terapia , Audición
11.
Sensors (Basel) ; 24(5)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38475083

RESUMEN

This paper provides a review of various machine learning approaches that have appeared in the literature aimed at individualizing or personalizing the amplification settings of hearing aids. After stating the limitations associated with the current one-size-fits-all settings of hearing aid prescriptions, a spectrum of studies in engineering and hearing science are discussed. These studies involve making adjustments to prescriptive values in order to enable preferred and individualized settings for a hearing aid user in an audio environment of interest to that user. This review gathers, in one place, a comprehensive collection of works that have been conducted thus far with respect to achieving the personalization or individualization of the amplification function of hearing aids. Furthermore, it underscores the impact that machine learning can have on enabling an improved and personalized hearing experience for hearing aid users. This paper concludes by stating the challenges and future research directions in this area.


Asunto(s)
Audífonos , Pérdida Auditiva Sensorineural , Humanos , Pérdida Auditiva Sensorineural/rehabilitación , Aprendizaje Automático
12.
Int J Pediatr Otorhinolaryngol ; 179: 111925, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38552429

RESUMEN

OBJECTIVE: The Baha SoundArc coupling system has been developed as a non-surgical coupling of a Baha sound processor to the skull allowing the transfer of vibrational energy to the cochlear partition via bone conduction pathways. Today, there are several alternatives to this non-surgical approach as the Baha headband/test band, or the Baha Softband, or adhesive patches. Each of these current options have benefits and liabilities. The aim of the study was to evaluate pediatric experience and performance when using two non-surgical options, the Baha SoundArc compared to the Baha Softband. METHODS: Twenty-five children with unilateral mixed or conductive hearing loss aged 5-12 years of age evaluated the use of the Baha SoundArc compared to their existing Baha Softband in a one month take home trial. Participants had a minimum of 3 months experience using the control, Baha Softband. Participants were assessed at baseline and one month following fit of the Baha SoundArc. Measures included an experience and use patient reported outcome, speech perception testing in quiet using Phonetically Balanced Kindergarten (PBK) words, and sound field audiometry. RESULTS: Mean aided soundfield thresholds across the frequency range were 27.6 dB HL for Softband and 26.0 dB HL for SoundArc, which were not significantly different (P = >.05). Mean word recognition score was 80.8% when aided with the Softband device and 85.1% with the SoundArc, which was also not significantly different (P = >.05). Most children favored the aesthetics and usability of the SoundArc over Softband, but comfort ratings were largely similar for both devices. CONCLUSIONS: Bone conduction sound processors mounted on a SoundArc or a Softband resulted in comparable improvements in aided thresholds and speech understanding in children suffering from conductive or mixed hearing loss. Both wearing modalities can be considered equivalent in terms of audiological outcomes, although both patients and clinicians preferred the usability and aesthetics of the SoundArc. The SoundArc provides an alternative wearing option for patients that may otherwise be discouraged by the aesthetics and usability of the Softband device. GOV IDENTIFIER: NCT03333577.


Asunto(s)
Audífonos , Pérdida Auditiva , Percepción del Habla , Humanos , Niño , Preescolar , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/terapia , Audiometría , Conducción Ósea
13.
Trends Hear ; 28: 23312165241227815, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38545698

RESUMEN

An objective method for assessing speech audibility is essential to evaluate hearing aid benefit in children who are unable to participate in hearing tests. With consonant-vowel syllables, brainstem-dominant responses elicited at the voice fundamental frequency have proven successful for assessing audibility. This study aimed to harness the neural activity elicited by the slow envelope of the same repetitive consonant-vowel syllables to assess audibility. In adults and children with normal hearing and children with hearing loss wearing hearing aids, neural activity elicited by the stimulus /su∫i/ or /sa∫i/ presented at 55-75 dB SPL was analyzed using the temporal response function approach. No-stimulus runs or very low stimulus level (15 dB SPL) were used to simulate inaudible conditions in adults and children with normal hearing. Both groups of children demonstrated higher response amplitudes relative to adults. Detectability (sensitivity; true positive rate) ranged between 80.1 and 100%, and did not vary by group or stimulus level but varied by stimulus, with /sa∫i/ achieving 100% detectability at 65 dB SPL. The average minimum time needed to detect a response ranged between 3.7 and 6.4 min across stimuli and listener groups, with the shortest times recorded for stimulus /sa∫i/ and in children with hearing loss. Specificity was >94.9%. Responses to the slow envelope of non-meaningful consonant-vowel syllables can be used to ascertain audible vs. inaudible speech with sufficient accuracy within clinically feasible test times. Such responses can increase the clinical usefulness of existing objective approaches to evaluate hearing aid benefit.


Asunto(s)
Sordera , Audífonos , Pérdida Auditiva Sensorineural , Pérdida Auditiva , Percepción del Habla , Adulto , Niño , Humanos , Habla , Percepción del Habla/fisiología , Pérdida Auditiva/diagnóstico , Pérdida Auditiva Sensorineural/rehabilitación
14.
Sci Rep ; 14(1): 7509, 2024 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-38553548

RESUMEN

Hearing loss affects some nutrient intake. Disabling hearing loss may exacerbate these issues. We aimed to evaluate nutrient intake and assess deficiencies based on functional hearing status. The study included 6907 participants with information on demographic factors, nutrient intake, weight, height, disease status, and hearing level in the eighth Korea National Health and Nutrition Examination Survey, conducted from 2019 to 2021. We categorized the participants into 3 groups based on their functional hearing status: bilateral hearing, unilateral hearing, and disabling hearing loss. The disabling hearing loss group showed lower intake of most major nutrients (P < 0.05), dietary fiber (P < 0.001), and most minerals and vitamins (P < 0.05), with some insufficiencies. The unilateral hearing group showed lower intake only for potassium (P = 0.036) compared to the bilateral hearing group and significantly higher intake of hydration (P = 0.039), dietary fiber (P = 0.039), and calcium (P = 0.009) than the disabling hearing loss group. Nutrient insufficiency in the disabling hearing loss group was more prominent in women, and was partially resolved by using hearing aids. Clinicians and nutritionists should consider undernourishment in these patients, and appropriate interventions for nutrition and hearing aids should be recommended.


Asunto(s)
Sordera , Audífonos , Pérdida Auditiva , Humanos , Femenino , Encuestas Nutricionales , Ingestión de Alimentos , Fibras de la Dieta , Dieta
15.
Trends Hear ; 28: 23312165231222098, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38549287

RESUMEN

This study measured electroencephalographic activity in the alpha band, often associated with task difficulty, to physiologically validate self-reported effort ratings from older hearing-impaired listeners performing the Repeat-Recall Test (RRT)-an integrative multipart assessment of speech-in-noise performance, context use, and auditory working memory. Following a single-blind within-subjects design, 16 older listeners (mean age = 71 years, SD = 13, 9 female) with a moderate-to-severe degree of bilateral sensorineural hearing loss performed the RRT while wearing hearing aids at four fixed signal-to-noise ratios (SNRs) of -5, 0, 5, and 10 dB. Performance and subjective ratings of listening effort were assessed for complementary versions of the RRT materials with high/low availability of semantic context. Listeners were also tested with a version of the RRT that omitted the memory (i.e., recall) component. As expected, results showed alpha power to decrease significantly with increasing SNR from 0 through 10 dB. When tested with high context sentences, alpha was significantly higher in conditions where listeners had to recall the sentence materials compared to conditions where the recall requirement was omitted. When tested with low context sentences, alpha power was relatively high irrespective of the memory component. Within-subjects, alpha power was related to listening effort ratings collected across the different RRT conditions. Overall, these results suggest that the multipart demands of the RRT modulate both neural and behavioral measures of listening effort in directions consistent with the expected/designed difficulty of the RRT conditions.


Asunto(s)
Audífonos , Pérdida Auditiva Sensorineural , Percepción del Habla , Humanos , Femenino , Anciano , Método Simple Ciego , Pérdida Auditiva Sensorineural/terapia , Pérdida Auditiva Sensorineural/rehabilitación , Ruido/efectos adversos
16.
Med Image Anal ; 94: 103152, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38531210

RESUMEN

Today, fitting bespoke hearing aids involves injecting silicone into patients' ears to produce ear canal molds. These are subsequently 3D scanned to create digital ear canal impressions. However, before digital impressions can be used they require a substantial amount of effort in manual 3D editing. In this article, we present computational methods to pre-process ear canal impressions. The aim is to create automation tools to assist the hearing aid design, manufacturing and fitting processes as well as normalizing anatomical data to assist the study of the outer ear canal's morphology. The methods include classifying the handedness of the impression into left and right ear types, orienting the geometries onto the same coordinate system sense, and removing extraneous artifacts introduced by the silicone mold. We investigate the use of convolutional neural networks for performing these semantic tasks and evaluate their accuracy using a dataset of 3000 ear canal impressions. The neural networks proved highly effective at performing these tasks with 95.8% adjusted accuracy in classification, 92.3% within 20° angular error in registration and 93.4% intersection over union in segmentation.


Asunto(s)
Conducto Auditivo Externo , Audífonos , Humanos , Conducto Auditivo Externo/anatomía & histología , Siliconas , Redes Neurales de la Computación
17.
Dan Med J ; 71(4)2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38533878

RESUMEN

INTRODUCTION: Capacity constraints in Danish hearing healthcare may lead to diagnostic delays and repetitive pre-treatment audiological exams for hearing-impaired patients. This study investigated the effectiveness of remote ear-nose-throat (ENT) specialist assessments (RESA) for complicated hearing loss, comparing the accuracy of private ENT specialists and medical audiologists. METHODS: RESA screening accuracy was determined for four ENT specialists, individually and as subspecialised groups. These assessments were benchmarked against "gold standard" in-person ENT assessments for 445 potential adult first-time hearing aid users. RESULTS: Medical audiologists initially recorded lower RESA screening specificity and positive predictive values than private ENT specialists. However, after making two adjustments to the dataset, these differences were neutralised. Screening sensitivity was consistent across individual and grouped subspecialities. CONCLUSIONS: RESA screening is a promising tool for timely diagnosis and treatment. The findings reveal that both private ENT specialists and medical audiologists may conduct RESA with high consistency and uniformity. FUNDING: This research was funded by the Danish Health Data Authority and the North Denmark Region, but does not reflect their views. The study received no commercial support. TRIAL REGISTRATION: Not relevant.


Asunto(s)
Audífonos , Pérdida Auditiva , Adulto , Humanos , Audición
18.
Am J Public Health ; 114(4): 407-414, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38478867

RESUMEN

Objectives. To produce a database of private insurance hearing aid mandates in the United States and quantify the share of privately insured individuals covered by a mandate. Methods. We used health-related policy surveillance methods to create a database of private insurance hearing aid mandates through January 2023. We coded salient features of mandates and combined policy data with American Community Survey and Medicare Expenditure Panel Survey-Insurance Component data to estimate the share of privately insured US residents covered by a mandate from 2008 to 2022. Results. A total of 26 states and 1 territory had private insurance hearing aid mandates. We found variability for mandate exceptions, maximum age eligibility, allowable frequency of benefit use, and coverage amounts. Between 2008 and 2022 the proportion of privately insured youths (aged ≤ 18 years) living where there was a private insurance hearing aid mandate increased from 3.4% to 18.7% and the proportion of privately insured adults (19-64 years) increased from 0.3% to 4.6%. Conclusions. Hearing aid mandates cover a small share of US residents. Mandate exceptions in several states limit coverage, particularly for adults. Public Health Implications. A federal mandate would improve hearing aid access. States can also improve access by adopting exception-free mandates with limited utilization management and no age restrictions. (Am J Public Health. 2024;114(4):407-414. https://doi.org/10.2105/AJPH.2023.307551).


Asunto(s)
Audífonos , Cobertura del Seguro , Adulto , Adolescente , Humanos , Estados Unidos , Anciano , Epidemiología del Derecho , Medicare , Política de Salud , Seguro de Salud
20.
Int Tinnitus J ; 27(2): 126-134, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38507625

RESUMEN

COVID - 19 (Corona Virus Infectious Disease) situations reported in 2019, declared by World Health Organization (WHO) as a pandemic is still a prevailing global crisis. Common regulations were implemented such as lockdown, wearing face masks as mandatory, face shields, gloves and maintaining physical and social distance in public places to reduce the spread of the virus. These pandemic induced challenges affected social communication, technical and behavioral aspects in lifestyle of people with hearing impairment. Along with medical, paramedical services, the crisis had challenged hearing, speech language pathology and therapy services too. The study aimed to explore the challenges that adults with hearing impairment had experienced during the pandemic and to suggest some practical solutions that can be implemented by audiologists. It is a questionnaire-based study with purposive sampling method employed in data collection. The questionnaire was administered on adult hearing aid users (mean age: 18 years) recruited for participation from different parts/ clinical setups across India. The outcome of the questionnaire did support the assumption that availing audiological services was difficult or impossible for most of the hearing aid users. Accessing batteries was reported to be the most frequent issue. Adequate level of hearing though hearing aid was important to them and clinical services could not be availed for long period of time due to travel related issues and closure of audiological services. Also, social isolation impacted on their quality of life and effective communication. As a possible solution most of the users chose tele services as a better solution.


Asunto(s)
COVID-19 , Audífonos , Pérdida Auditiva , Adulto , Humanos , Adolescente , COVID-19/epidemiología , COVID-19/prevención & control , Pandemias , Proyectos Piloto , Calidad de Vida , Viaje , Control de Enfermedades Transmisibles , Enfermedad Relacionada con los Viajes , Pérdida Auditiva/epidemiología , Pérdida Auditiva/rehabilitación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...